REQUIRED ROUGH OPENING FOR DOOR AND FRAME INSTALLATION IN MASONRY / CONCRETE

SINGLE-DOOR WIDTH

Nominal Door Size

Required Rough Opening (Meters / Feet-Inches)

Meters

Feet-Inches

0.61

2′-0″

0.715 / 2′-4″

0.71

2′-4″

0.815 / 2′-8″

0.76

2′-6″

0.865 / 2′-10″

0.81

2′-8″

0.915 / 3′-0″

0.865

2′-10″

0.97 / 3′-2″

0.915

3′-0″

1.02 / 3′-4″

1.015

3′-4″

1.12 / 3′-8″

1.07

3′-6″

1.175 / 3′-10″

1.12

3′-8″

1.225 / 4′-0″

1.17

3′-10″

1.275 / 4′-2″

1.22

4′-0″

1.325 / 4′-4″

PAIR-OF-DOORS WIDTH

Nominal Door Size

Required Rough Opening (Meters / Feet-Inches)

Meters

Feet-Inches

1.22

4′-0″

1.325 / 4′-4″

1.42

4′-8″

1.525 / 5′-0″

1.525

5′-0″

1.63 / 5′-4″

1.625

5′-4″

1.73 / 5′-8″

1.73

5′-8″

1.835 / 6′-0″

1.83

6′-0″

1.935 / 6′-4″

2.035

6′-8″

2.14 / 7′-0″

2.135

7′-0″

2.24 / 7′-4″

2.235

7′-4″

2.34 / 7′-8″

2.34

7′-8″

2.445 / 8′-0″

2.44

8′-0″

2.545 / 8′-4″

HEIGHT

Nominal Door Size

Required Rough Opening (Meters / Feet-Inches)

Meters

Feet-Inches

2.035

6′-8″

2.09 / 6′-10″

2.135

7′-0″

2.19 / 7′-2″

2.185

7′-2″

2.24 / 7′-4″

2.44

8′-0″

2.495 / 8′-2″


 

REQUIRED ROUGH OPENING FOR DOOR AND KNOCK-DOWN FRAME INSTALLATION IN DRYWALL

SINGLE-DOOR WIDTH

Nominal Door Size

Required Rough Opening (Meters / Feet-Inches)

Meters

Feet-Inches

0.61

2′-0″

0.66 / 2′-2″

0.71

2′-4″

0.76 / 2′-6″

0.76

2′-6″

0.81 / 2′-8″

0.81

2′-8″

0.86 / 2′-10″

0.865

2′-10″

0.915 / 3′-0″

0.915

3′-0″

0.965 / 3′-2″

1.015

3′-4″

1.065 / 3′-6″

1.07

3′-6″

1.12 / 3′-8″

1.12

3′-8″

1.17 / 3′-10″

1.17

3′-10″

1.22 / 4′-0″

1.22

4′-0″

1.27 / 4′-2″

PAIR-OF-DOORS WIDTH

Nominal Door Size

Required Rough Opening (Meters / Feet-Inches)

Meters

Feet-Inches

1.22

4′-0″

1.27 / 4′-2″

1.42

4′-8″

1.47 / 4′-10″

1.525

5′-0″

1.575 / 5′-2″

1.625

5′-4″

1.675 / 5′-6″

1.73

5′-8″

1.75 / 5′-10″

1.83

6′-0″

1.88 / 6′-2″

2.035

6′-8″

2.085 / 6′-10″

2.135

7′-0″

2.185 / 7′-2″

2.235

7′-4″

2.285 / 7′-6″

2.34

7′-8″

2.39 / 7′-10″

2.44

8′-0″

2.49 / 8′-2″

HEIGHT

Nominal Door Size

Required Rough Opening (Meters / Feet-Inches)

Meters

Feet-Inches

2.035

6′-8″

2.06 / 6′-9″

2.135

7′-0″

2.16 / 7′-1″

2.185

7′-2″

2.21 / 7′-3″

2.44

8′-0″

2.47 / 8′-1″